Pegasus Range
600W and 1600W 19” rack PSU for general use
| Basic Specification | DC High Voltage Power Supplies suitable predominantly for laboratory use but optional grid and fi laments also makes this range of supply suitable for electron beam systems and x-ray applications. Standard remote control is by analogue signals but should other controls be preferred please discuss this with our technical staff. Available in a standard 19-inch rack. Reduced weight and ease of serviceability is ensured, as the supplies are air insulated. | |||||||||||||||
| Type 600 WATT |
|
|||||||||||||||
| |
|
|||||||||||||||
| Type 1600 WATT |
|
|||||||||||||||
| |
|
|||||||||||||||
| Performance Parameters | P1600/40 | |||||||||||||||
| Ripple | Not more than 20V (peak to peak) - 100W Version | |||||||||||||||
| Temperature coefficient | |
|||||||||||||||
| Output voltage and current | Output Voltage: 0 to 40kV Output Voltage: 0 to 40mA |
|||||||||||||||
| Line regulation | Not more than 100ppm of maximum rated output voltage for ± 10% input line change. | |||||||||||||||
| Load regulation | Not more than 100ppm of maximum rated output voltage for 10% to maximum output current change. |
|||||||||||||||
| Ripple | Not more than 20V (peak to peak) | |||||||||||||||
| Temperature coefficient (0 to 50°C) |
Typically not more than 100ppm of maximum output per °C | |||||||||||||||
| Stability after 1⁄2 hour settling period | Not more than 0.04% per hour Not more than 0.05% per 8 hours. |
|||||||||||||||
| Optional adittion & outputs | Isolated grid output available up to 2000V @ 10mA Isolated fi lament available up to 10V @ 10A |
|||||||||||||||
| |
|
|||||||||||||||
| Remote Control | |
|||||||||||||||
| Analogue control inputs | 0 to 10V = 0 to 40kV - Voltage Programming 0 to 10V = 0 to 40mA - Current Programming Please discuss RS232 or IEEE 488 requirements |
|||||||||||||||
| |
|
|||||||||||||||
| Front Panel Feature | |
|||||||||||||||
| Front panel meters | Although both units are designed with remote control as standard, they are both compatible with the Genvolt standard external front panel module. If front panel controls are required please consult our technical staff. | |||||||||||||||
| Front panel controls | Front panel control with readouts is available for output voltage and current control. | |||||||||||||||
| Protection | The power supplies are protected against overloads, short circuits and arcs | |||||||||||||||
| |
||||||||||||||||
| Mechanical Features | |
|||||||||||||||
| Size | 19 inch wide suitable for standard rack mounting. 4U High for above specifi cation. (2U for Type 600W) | |||||||||||||||
| Weight | Approx. 20kg (Type 1600W) | |||||||||||||||
| Cooling | Forced air by means of internal fans. | |||||||||||||||
| Power requirements | 230V AC ±10% Single phase. All models | |||||||||||||||
| |
||||||||||||||||
| Enviromental Requirements | |
|||||||||||||||
| Temperature | Operating: 0°C to 35°C. Storage 0°C to 60°C. |
|||||||||||||||
| Relative humidity | Operating: 30% to 80%. Storage: <95%. |
|||||||||||||||
| |
Design improvements may lead to specification changes. |